Tuesday, September 25, 2012

Tripp Lite Isolation Transformer IS250HG - Transformer - AC 120 V - 250 Watt - 2 output connector(s)

Tripp Lite Isolation Transformer IS250HG - Transformer - AC 120 V - 250 Watt - 2 output connector(s)


Tripp Lite Isolation Transformer IS250HG - Transformer - AC 120 V - 250 Watt - 2 output connector(s)


see large image Tripp Lite Isolation Transformer IS250HG - Transformer - AC 120 V - 250 Watt - 2 output connector(s)
sp price




Tripp Lite Isolation Transformer IS250HG - Transformer - AC 120 V - 250 Watt - 2 output connector(s) Description


Tripp Lite Isolator series UL2601-1 listed Hospital Grade isolation transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. Internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL2601-1 medical grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for the protection of sensitive electronic equipment in patient-care areas. Isolation transformer with Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels below 300 microamps. Secondary neutral to ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment and an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients, and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offers continuous filtering of a full range of power line noise in all modes. Active transformer filtering offers continuous common-mode noise rejection with no wearable parts, uniquely able to reduce surges in the worst of power environments to harmless levels. It reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS250HG includes 2 widely spaced NEMA5-15R hospital grade output receptacles, a 6-ft power cord, hospital grade input plug, circuit breaker overload protection and lighted power switch. Rugged all-metal unit housing ships ready for placement in any industrial, medical, office or network environment.

Specifications

General
   Device Type:  Transformer - external
   Width:  4.8 in
   Depth:  7.8 in
   Height:  4.5 in
   Weight:  13.9 lbs

Power Device
   Input Voltage:  AC 120 V
   Frequency Required:  60 Hz
   Input Connector(s):  1 x power NEMA 5-15
   Output Voltage:  AC 120 V ( 60 Hz )
   Power Output Connectors Details:  2 x power NEMA 5-15
   Power Capacity:  250 Watt
   Surge Energy Rating:  680 Joules
   EMI/RFI Noise Filtration:  65 dB
   Circuit Protection:  Circuit breaker

Miscellaneous
   Cables Included:  1 x power cable - integrated - 6 ft
   Compliant Standards:  UL, cUL, UL 2601-1

Manufacturer Warranty
   Service & Support:  2 years warranty
   Service & Support Details:  Limited warranty - 2 years
Tripp Lite Isolation Transformer IS250HG - Transformer - AC 120 V - 250 Watt - 2 output connector(s)


Tripp Lite Isolation Transformer IS250HG - Transformer - AC 120 V - 250 Watt - 2 output connector(s)


see large image Tripp Lite Isolation Transformer IS250HG - Transformer - AC 120 V - 250 Watt - 2 output connector(s)


Now! Special price Click Here








Tripp Lite Isolation Transformer IS250HG - Transformer - AC 120 V - 250 Watt - 2 output connector(s)

No comments: